Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets

SKU:
NFC161208VFHA1-Z
Availability:
Usually Ships in 1 to 2 Business Days
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Bonus Key Included with Enclosure!
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Altelix 16x12x8 Vented Insulated Fiberglass Heated Weatherproof NEMA Enclosure with Cooling Fan, 200W Heater and 120 VAC Outlets
  • Cable Gland
  • Scale Reference
Your Price: $724.99

Get simple modifications in only 3-5 days! Click to learn more.

For customization and volume pricing inquiries please Click Here to email us at sales@altelix.com

Description

Features
  • Heavy Duty Fiberglass Reinforced Polyester (FRP) Construction
  • Includes Equipment Mounting Plate
  • Dual 4" Vents and Thermostat Controlled Cooling Fan
  • Thermostat Controlled 200W Heating System
  • 1/2" Thick Insulation Bonded to Interior of Enclosure
  • 120VAC Outlets
  • Dual Quarter-Turn Door Latches
  • Bonus Aluminum Bottle Opener Key Now Included!
  • (4) Mounting Feet Included
  • NEMA Type 3R, 3RX / IP24 Rated
  • Optional Lockable Latch Sets Available
Applications
  • Outdoor WiFi Installations
  • SCADA, Remote Terminal Unit
  • Security and Video Surveillance NVR Systems
  • Protection of Equipment from Theft or Damage
  • Concealment of Equipment
  • Tunnel and Mining Installations
  • Railroad Facilities
  • Mills & Refineries
  • Cement and Chemical Plants
  • Food Processing Facilities
  • Warehouses and Loading Docks
  • Marinas and Marine Terminals
  • Golf Courses, Resort Properties and Recreational Areas
  • Building Maintenance Areas
  • Building Rooftop or Basement
  • Parking Lots and Garages
  • Weather Stations

 

Note: THIS IS A SPECIAL ORDER ITEM.

The Altelix NFC161208VFHA1-Z Insulated Heated and Fan Cooled Weatherproof NEMA Enclosure with 120VAC Power and Equipment Mounting Plate is ideal for protecting equipment from harsh environments and tampering. Equipment designed for indoor use can now be located outside.

Construction and Features
This rugged enclosure is molded from durable and UV resistant fiberglass reinforced polyester (FRP). The door is fully gasketed making this enclosure suitable for use indoors or outdoors. The lockable door features reinforced hinges and dual quarter-turn latches to secure the enclosure and is locked and unlocked using the included removable keys. A drip rail over the door provides additional protection against water dripping into the cabinet while the enclosure is wet.

Bonus Aluminum Bottle Opener Key
This enclosure now includes our HN-0008 Aluminum Bottle Opener Key. A $9.99 value, this heavy duty aluminum door locking key easily attaches to most key chains. And it makes a great bottle opener too!

Power
This configuration consists of the vented fiberglass NEMA enclosure with hinged lid and a equipment mounting plate with two pre-wired 120VAC power outlets. The outlet box is easily removable to facilitate wiring to an external power source.

Cooling Fan Ventilation
This enclosure features dual 4" vents and a thermostat controlled cooling fan. The low noise, high airflow fan helps maintain lower internal temperatures. The fan turns on when the internal temperature reaches 100°F (38°C) and turns off when it drops to 79°F (26°C). The fan is wired internally so it does not require the use of the AC outlets leaving them available for internal equipment use. Rain shrouds on the front door keep rain water from entering the enclosure, and the internal aluminum mesh filters are removable for cleaning. Dual fans are also available by request.

Heater
Ideal for cold environments, this model also features a thermostat controlled 200W heating system. The heater turns on when the internal temperature reaches 43°F (6°C) and turns off when it rises to 59°F (15°C). The heater is situated below the mounting plate and wired internally so it does not interfere with user installed equipment or require the use of the AC outlets.

Insulated Enclosure
Designed for extreme cold and hot environments, the NFC161208VFHA1-Z features 0.500 inch (12.7mm) thick insulation bonded to all interior sides of the enclosure.

Equipment Mounting Plate
The equipment mounting plate is provided for mounting and securing equipment. The enclosure and plate can be drilled and modified by the installer to suit unique site requirements.

Cable Glands
The enclosure features our unique PG-16 cable glands with a closed inner seal. They are installed in the open ports to maintain the NEMA rating of the enclosure when not in use. When required for use, simply punch a hole through the inner membrane, run your cables and tighten for a water-tight seal.

Mounting
Four mounting feet are included so that the enclosure can be securely mounted to a wall or other structure. Two optional flange and pole mounting kits are available, painted steel (model NMKS-300-08) and stainless steel (model NMKX-300-08).

Optional Lockable Latches
For additional protection of internal equipment installed, three lockable latches are available. The HN-0005 is a keyed lock set which includes two keys. Similar to the HN-0005, the HN-0001 has an interlock feature that traps the key when it is in the unlocked position. The HN-0006 allows the enclosure to be securely locked via use of a padlock (not included). All of these optional lockable latches are direct replacements for the standard quarter-turn latches that come pre-installed in the enclosures.

Customization
This enclosure is one of many possible configurations available by special order. We offer many options including equipment mounting plates, DIN rails, AC or DC power, air vents, cooling fans and heaters and more. We also offer full customization, engineering and on-site CNC machining of enclosures and associated equipment, all with quick turnaround time. For pricing and availability inquiries please contact us with your specific project requirements and quantities.

Technical Specifications

Material Fiberglass Reinforced Polyester
Color Light Gray
Voltage 120VAC
Max Load 15A @ 120VAC
Cooling Fan Turn-On Temperature 100°F (38°C) ±6°F
Cooling Fan Turn-Off Temperature 79°F (26°C) ±9°F
Heater Turn-On Temperature 43°F (6°C) ±5°F
Heater Turn-Off Temperature 59°F (15°C) ±5°F
Heater Power 200 Watts
Insulation Thickness 0.500 Inch (12.7 mm)
Insulation R-Value 2
Outer Dimensions 15.7 x 11.9 x 9.4 Inches
(398 x 302 x 239 mm)
Inner Dimensions* 10.5 x 10.0 x 3.7 Inches
(267 x 254 x 95 mm)
Equipment Plate Dimensions 9.7 x 13.9 In. (246 x 353 mm)
Weight 12 lbs. (5.4 kg)
Ratings NEMA Type 3R, 3RX / IP24
*Interior dimensions represent space available for equipment. See drawing for additional details.


 

NEMA Ratings and IP Equivalency Chart
This chart provides the different NEMA ratings and their definitions as well as the IP equivalents and definitions.

 

Need a pole mount kit or an extra set of enclosure keys? Click on ADD TO CART below to see all the available accessories for this enclosure.

View AllClose

Warning WARNING: This product can expose you to chemicals including phthalates, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.p65warnings.ca.gov